Contact Form

Radiation Cross-linked Polyethylene Heat Shrinkable Tape (Lap Joint)

PRODUCT PARAMETERS

Description
FAQs
Request A Quote

Description

Viscoelastic anti-corosion tape (paste)is a newly developed anti-corrosion product specifically designed for underground pipelines and other iregularly shaped cqupmen such as tanges, valves., pumps, ete. Dhe seues of viscoclastic ant couusion lapes ofter advantages including simple and convenicnt application. excetlent sealing perfomance. long lasing anti corosion lifespan, and complete eanvirommental friendliness, making them an ideal choice corrosion protection.Their performance indicators comply with the requirements specified in Document No.DEC-OGP S-AC-007-2020-1 of the ” Techmical Speciticatons for Viscoelastic Anti-Corrosion Materials in Oil and Gas Pipeline Enginecring” For irregularly shaped and uneven workpieces such as valves, flanges. pipe joints, and bolts, anti -corrosion paste is applied to fill in depressions and create a smooth surface,preventing bridging or voids when wrapping the anti-corrosion tape later.

Installation Guide & Precautions

Important: These instructions apply to both the roll and sheet formats of the Heat Shrinkable Tape (Lap Joint).

Quick Installation Steps

  1. Surface preparation: Clean and blast the weld area to Sa2.5级. Grind smooth any weld irregularities.
  2. Pipe preheating: Preheat the pipe around the weld to the temperature recommended by the primer manufacturer (typically 75°C-85°C).
  3. Primer application: Apply solvent-free epoxy primer to the prepared area.
  4. Position the tape:
    • For rolls: Wrap the tape around the pipe, ensuring a minimum 100mm circumferential overlap.
    • For sheets: Position the sheet over the weld area with the required longitudinal overlap.
  5. Install fixing strip: Secure the overlap seam with the provided fixing strip.
  6. Heat shrinking: Using a propane torch, heat the tape evenly from the center outward. Shrink until the adhesive flows out slightly at both ends.
  7. Final inspection: Check for smooth coverage, no bubbles, and full adhesion at the overlaps and pipe ends.

Key Reminders

  • Do not overheat – Excessive heat can burn the backing. Keep the torch moving.
  • Shrink from the center – This prevents air entrapment.
  • Check overlap – A minimum 100mm overlap is critical.
  • Storage: Keep in original packaging in a dry area below 35°C, away from sunlight.

FAQs